The hotfix went in. Most tills came back. One POS now stops at start-up with a version or update-required message, and the store is a till down before trading starts. Before forcing anything, read the message in full: a mismatch is a comparison between specific version numbers, and the fix depends entirely on which numbers disagree.

The error first: read exactly which versions the POS is comparing

Copy the complete error text, the terminal name, and the versions the POS reports, before restarting or reinstalling. Two different problems hide behind similar start-up failures. One is a genuine bundle mismatch, where the components on the till do not agree with each other. The other is a lookalike sign-in block with a different cause and a different fix, covered below. Restarting first destroys the evidence that separates them.

Also record the fleet picture at the same time: how many tills updated, how many did not, and whether the failing till missed the rollout or received it and still disagrees. A partial rollout and a broken bundle need different handling.

Three numbers, one bundle: platform, app, and LS Central version

The POS runs as a bundle of components, and the bundle pins its components to three version values. The documented dependency structure is:

ComponentPinned to
ls-hardware-stationLsCentralVersion
ls-central-app-runtimeLsCentralVersion
bc-web-clientBcPlatformVersion
bc-application (in the older Hybrid model, carried by a separate POS Master bundle, with the license)BcAppVersion

That table turns a vague mismatch into a specific question. If the hardware station and the app runtime disagree with the rest, the LS Central version is the suspect. If the web client disagrees, the platform version is the suspect. Diagnose from the bundle structure rather than updating every component in the hope that one of them was the problem.

The lookalike: Universal Code sign-in blocks after platform updates

One documented error reads: “Sorry, we can’t sign you in because the following apps don’t meet our Universal Code requirement.” It looks like a version mismatch, and it appears around platform updates, but the documented cause is different: it can occur on a machine running a Business Central version with a known bug.

The documented resolution is to update the Business Central platform to the latest cumulative update within the major version. Apps do not necessarily need updating. That distinction saves a needless app redeploy: if the error text matches the Universal Code message, the platform cumulative update is the fix to try, on its own.

Force the update: Update Service client, bundle redeploy, and restart order

Work in this order, changing one version at a time:

  1. Check the hotfix notes first. LS Central hotfix entries repeatedly state the pattern “Action required by partners: None, the fix applies automatically once the updated version or hotfix is installed.” If the relevant fix carries that note, the till’s problem is delivery, the updated version has not landed there, not a missing partner action.
  2. For scaffolded projects, update the platform value in the project file. The documented step is to update the BcPlatformVersion property in Project.json, then follow the Update POS Application and Platform procedure. The troubleshooting example shows a project carrying an LsCentralVersion of 21.4.0 while its platform moves to a later build, which is exactly the shape of a platform-side mismatch.
  3. For the Universal Code lookalike, apply the latest platform cumulative update within the major version and re-test sign-in before touching the apps.
  4. Redeploy the bundle so the pinned components land together, rather than updating components one by one on the till. The bundle is the unit whose internal versions must agree.
  5. Restart and read the versions again. Compare the reported platform, app and LS Central versions against the bundle table above before declaring the till fixed.

What success looks like: the POS starts, signs in, and reports component versions that match the pins in the bundle. LsCentralVersion components together, bc-web-client at BcPlatformVersion, and, where the Hybrid model applies, bc-application at BcAppVersion.

Mixed fleet triage: trade safely on updated tills, quarantine the rest

Fleet stateDecision
A till updated and its reported versions match the bundle pinsTrade on it; it is the reference the other tills should match
A till shows the Universal Code sign-in messageApply the platform cumulative update path; do not redeploy apps first
A till missed the rollout and runs the previous bundle consistentlySchedule its update deliberately; a consistent old bundle is a known state, a half-updated one is not
A till has mixed component versions that match no bundleKeep it out of service until the bundle is redeployed as one unit

The triage principle is consistency over speed. A till whose components agree with each other, even on the previous version, is in a defined state. A till with a mixture that matches no documented bundle is the risk, regardless of how new its newest component is.

Verification: version report per terminal before the next hotfix window

  1. For every terminal, record the reported platform, app and LS Central versions in one list.
  2. Check each terminal against the bundle pins: LS Central components at LsCentralVersion, bc-web-client at BcPlatformVersion, bc-application at BcAppVersion where the Hybrid model applies.
  3. Flag any terminal that disagrees, and any terminal whose versions match no other terminal in the fleet.
  4. Keep the list with the hotfix record, so the next hotfix window starts from a known fleet state instead of a memory of one.

What success looks like: every terminal appears on the list, every version matches its pin, and there are no unexplained one-offs. The next mismatch, when it comes, will then be a short comparison against this report, not a fresh investigation at opening time.